Label: OXYGEN gas
-
NDC Code(s):
55728-100-01,
55728-100-02,
55728-100-03,
55728-100-04, view more55728-100-05, 55728-100-06, 55728-100-07, 55728-100-08, 55728-100-09, 55728-100-10, 55728-100-11, 55728-100-12, 55728-100-13, 55728-100-14, 55728-100-15, 55728-100-16
- Packager: A&B Welding Supply, LLC
- Category: HUMAN PRESCRIPTION DRUG LABEL
- DEA Schedule: None
- Marketing Status: New Drug Application
Drug Label Information
Updated November 18, 2025
If you are a consumer or patient please visit this version.
- Download DRUG LABEL INFO: PDF XML
- Official Label (Printer Friendly)
-
PRINCIPAL DISPLAY PANEL
OXYGEN, COMPRESSED USP
UN1072
PRODUCED BY AIR LIQUEFACTION
WARNING: For emergency use only when administered by properly trained personnel for oxygen deficiency and resuscitation. For all other medical applications, Rx required. Uninterrupted use of high concentrations of oxygen over a long duration, without monitoring its effect on oxygen content of arterial blood, may be harmful. Do not attempt to use on patients who have stopped breathing unless used in conjunction with resuscitative equipment.
DANGER: MAY CAUSE OR INTENSIFY FIRE; OXIDIZER. CONTAINS GAS UNDER PRESSURE; MAY EXPLODE IF HEATED. Obtain, read and follow all safety instructions before use. Keep away from clothing and other combustible materials. Keep valves and fittings free from grease and oil. Use and store only outdoors or with adequate ventilation. Store in a well-ventilated place. In case of fire: Stop leak if safe to do so. Use a back flow preventive device in the piping. Use only equipment of compatible materials of construction and rated for cylinder pressure. Use only with equipment cleaned for oxygen service. Do not open valve until connected to equipment prepared for use. Open valve slowly. Close valve after each use and when empty. Protect from sunlight when ambient temperature exceeds 52 C (125 F). Read and follow the Safety Data Sheet (SDS) before use. CAS: 7782-44-7 DO NOT REMOVE THIS PRODUCT LABEL.
AB WELDING SUPPLY
914 East Chicago Street
Rapid City, SD 57701
605-674-7523
NO SMOKING
NO VAPING
CONTENTS: LTRS: CU.FT.

-
PRINCIPAL DISPLAY PANEL
OXYGEN, COMPRESSED USP
UN1072
WARNING: For emergency use only when administered by properly trained personnel for oxygen deficiency and resuscitation. For all other medical applications, Rx required. Uninterrupted use of high concentrations of oxygen over a long duration, without monitoring its effect on oxygen content of arterial blood, may be harmful. Do not attempt to use on patients who have stopped breathing unless used in conjunction with resuscitative equipment. Produced by Air Liquefaction. DANGER: MAY CAUSE OR INTENSIFY FIRE; OXIDIZER. CONTAINS GAS UNDER PRESSURE; MAY EXPLOD IF HEATED. Obtain, read and follow all safety instructions before use. Keep away from clothing and other combustible materials. Keep valves and fittings free from grease and oil. Use and store only outdoors or with adequate ventilation. Store in a well-ventilated place. In case of fire: Stop leak if safe to do so. Use a back flow preventive device in the piping. Use only equipment of compatible materials of construction and rated for cylinder pressure. Use only with equipment cleaned for oxygen service. Do not open valve until connected to equipment prepared for use. Open valve slowly. Close valve after each use and when empty. Protect from sunlight when ambient temperature exceeds 52 C (125 F). Read and follow the Safety Data Sheet (SDS) before use. CAS: 7782-44-7
DO NOT REMOVE THIS PRODUCT LABEL.
AB WELDING SUPPLY
914 East Chicago Street
Rapid City, SD 57701
605-674-7523
NO SMOKING
NO VAPING
CONTENTS: LTRS: CU.FT.

-
PRINCIPAL DISPLAY PANEL
OXYGEN, COMPRESSED USP
UN1072
C.A.S. NO. 7782-44-7
Contents LTRS. CU.FT.
WARNING: For emergency use only when administered by properly trained personnel for oxygen deficiency and resuscitation. For all other medical applications, Rx required. Uninterrupted use of high concentrations of oxygen over a long duration, without monitoring its effect on oxygen content of arterial blood, may be harmful. Do not attempt to use on patients who have stopped breathing unless used in conjunction with resuscitative equipment.
DANGER: MAY CAUSE OR INTENSIFY FIRE; OXIDIZER. CONTAINS GAS UNDER PRESSURE; MAY EXPLODE IF HEATED. Obtain, read and follow all safety instructions before use. Keep away from clothing and other combustible materials. Keep valves and fittings free from grease and oil. Use and store only outdoors or with adequate ventilation. Store in a well-ventilated place. In case of fire: Stop leak if safe to do so. Use a back flow preventive device in the piping. Use only with equipment of compatible materials of construction and rated for cylinder pressure. Use only with equipment cleaned for oxygen service. Do not open valve until connected to equipment prepared for use. Open valve slowly. Close valve after each use and when empty. Protect from sunlight when ambient temperature exceeds 52 C (125 F). Read and follow the Safety Data Sheet (SDS) before use.
DO NOT REMOVE THIS PRODUCT LABEL.
AB WELDING SUPPLY
914 East Chicago Street
Rapid City, SD 57701
605-674-7523
NO SMOKING
NO VAPING

-
PRINCIPAL DISPLAY PANEL
REFRIGERATED LIQUID
OXYGEN, REFRIGERATED LIQUID USP
UN1073
ALWAYS KEEP CONTAINER IN UPRIGHT POSITION.
DO NOT CHANGE OR FORCE FIT CONNECTIONS.
CONTENTS: LTRS: CU.FT.
WARNING: For emergency use only when administered by properly trained personnel for oxygen deficiency and resuscitation. For all other medical applications, Rx required.
Uninterrupted use of high concentrations of oxygen over a long duration, without monitoring its effect on oxygen content of arterial blood, may be harmful. Do not attempt to use on patients who have stopped breathing unless used in conjunction with resuscitative equipment.Produced by Air Liquefaction.
DANGER: MAY CAUSE OR INTENSIFY FIRE; OXIDIZER. CONTAINS REFRIGERATED GAS; MAY CAUSE CRYOGENIC BURNS OR INJURY. COMBUSTIBLES IN CONTACT WITH OXIDIZING REFRIGERATED LIQUIDS MAY EXPLODE ON IGNITION OR IMPACT.
Obtain, read and follow all safety instructions before use. Keep away from clothing and other combustible materials. Keep valves and fittings free from grease and oil. Use only outdoors or with adequate ventilation. Store in a well-ventilated place. Wear cold insulating gloves and either face shield or eye protection. In case of fire: Stop leak if safe to do so. Use a back flow preventive device in the piping. Use only with equipment of compatible materials of construction and rated for cylinder pressure. Use only with equipment cleaned for oxygen service. DO NOT change or force fit connections. Avoid spills. Do not walk on or roll equipment over spills. Do not open valve until connected to equipment prepared for use. Open valve slowly. Close valve after each use and when empty. Always keep container in upright position. Read and follow the Safety Data Sheet (SDS) before use.
FIRST AID: IF ON SKIN: Thaw frosted parts with lukewarm water. Do not rub affected area. Get immediate medical help.
CAS: 7782-44-7
DO NOT REMOVE THIS PRODUCT LABEL.
AB WELDING SUPPLY
914 East Chicago Street
Rapid City, SD 57701
605-674-7523
NO SMOKING
NO VAPING

-
INGREDIENTS AND APPEARANCE
OXYGEN
oxygen gasProduct Information Product Type HUMAN PRESCRIPTION DRUG Item Code (Source) NDC:55728-100 Route of Administration RESPIRATORY (INHALATION) Active Ingredient/Active Moiety Ingredient Name Basis of Strength Strength OXYGEN (UNII: S88TT14065) (OXYGEN - UNII:S88TT14065) OXYGEN 990 mL in 1 L Packaging # Item Code Package Description Marketing Start Date Marketing End Date 1 NDC:55728-100-01 8070 L in 1 CYLINDER; Type 0: Not a Combination Product 01/02/1978 2 NDC:55728-100-02 7050 L in 1 CYLINDER; Type 0: Not a Combination Product 01/02/1978 3 NDC:55728-100-03 4360 L in 1 CYLINDER; Type 0: Not a Combination Product 01/02/1978 4 NDC:55728-100-04 2350 L in 1 CYLINDER; Type 0: Not a Combination Product 01/02/1978 5 NDC:55728-100-05 3284 L in 1 CYLINDER; Type 0: Not a Combination Product 01/02/1978 6 NDC:55728-100-06 170 L in 1 CYLINDER; Type 0: Not a Combination Product 01/02/1978 7 NDC:55728-100-07 124 L in 1 CYLINDER; Type 0: Not a Combination Product 01/02/1978 8 NDC:55728-100-08 164 L in 1 CYLINDER; Type 0: Not a Combination Product 01/02/1978 9 NDC:55728-100-09 425 L in 1 CYLINDER; Type 0: Not a Combination Product 01/02/1978 10 NDC:55728-100-10 622 L in 1 CYLINDER; Type 0: Not a Combination Product 01/02/1978 11 NDC:55728-100-11 160 L in 1 CYLINDER; Type 0: Not a Combination Product 01/02/1978 12 NDC:55728-100-12 196 L in 1 CYLINDER; Type 0: Not a Combination Product 01/02/1978 13 NDC:55728-100-13 618893 L in 1 CYLINDER; Type 0: Not a Combination Product 01/02/1978 14 NDC:55728-100-14 248 L in 1 CYLINDER; Type 0: Not a Combination Product 01/02/1978 15 NDC:55728-100-15 589 L in 1 CYLINDER; Type 0: Not a Combination Product 01/02/1978 16 NDC:55728-100-16 646 L in 1 CYLINDER; Type 0: Not a Combination Product 01/02/1978 Marketing Information Marketing Category Application Number or Monograph Citation Marketing Start Date Marketing End Date NDA NDA205767 01/02/1978 Labeler - A&B Welding Supply, LLC (007499460) Registrant - A&B Welding Supply, LLC (007499460) Establishment Name Address ID/FEI Business Operations A&B Welding Supply, LLC 007499460 manufacture(55728-100)