Label: FLUOCINOLONE ACETONIDE cream

  • Category: HUMAN PRESCRIPTION DRUG LABEL

Drug Label Information

Updated February 22, 2011

If you are a healthcare professional or from the pharmaceutical industry please visit this version.

  • SPL UNCLASSIFIED SECTION

    For Dermatologic Use Only - Not for Ophthalmic Use.

    Rx Only

  • DESCRIPTION

    Fluocinolone Acetonide Cream contains Fluocinolone Acetonide USP (Pregna-1,4-diene-3,20-dione, 6,9-difluoro-11,21-dihydroxy-16,17-[(1-methylethylidene)-bis(oxy)]-, (6α,11β,16α)-); it has a empirical formula of C 24 H 30 F 2 O 6 and a molecular weight of 452.49 (CAS Registry Number 67-73-2).

    Each gram of the 0.01% cream contains 0.1 mg of Fluocinolone Acetonide in a base containing Stearic Acid, Propylene Gycol, Sorbitan Monostearate and Monooleate, Polysorbate 60, Citric Acid, Methylparaben, Propylparaben and Purified Water.

    Each gram of the 0.025% cream contains 0.25 mg of Fluocinolone Acetonide in a base containing Stearic Acid, Propylene Gycol, Sorbitan Monostearate and Monooleate, Polysorbate 60, Citric Acid, Methylparaben, Propylparaben and Purified Water.


    Structure Image


  • CLINICAL PHARMACOLOGY

    Topical corticosteroids share anti-inflammatory, anti-pruritic and vasoconstrictive actions. The mechanism of anti-inflammatory activity of the topical corticosteroids is unclear. Various laboratory methods, including vasoconstrictor assays, are used to compare and predict potencies and/or clinical efficacies of the topical corticosteroids. There is some evidence to suggest that a recognizable correlation exists between vasoconstrictor potency and therapeutic efficacy in man.

    Pharmacokinetics: The extent of percutaneous absorption of topical corticosteroids is determined by many factors including the vehicle, the integrity of the epidermal barrier, and the use of occlusive dressings. Topical corticosteroids can be absorbed from normal intact skin. Inflammation and/or other disease processes in the skin increase percutaneous absorption. Occlusive dressings substantially increase the percutaneous absorption of topical corticosteroids. Thus, occlusive dressings may be a valuable therapeutic adjunct for treatment of resistant dermatoses. (SeeDOSAGE AND ADMINISTRATION ). Once absorbed through the skin, topical corticosteroids are handled through pharmacokinetic pathways similar to systemically administered corticosteroids. Corticosteroids are bound to plasma proteins in varying degrees. Corticosteroids are metabolized primarily in the liver and are then excreted by the kidneys. Some of the topical corticosteroids and their metabolites are also excreted in the bile.

  • INDICATIONS AND USAGE

    Topical corticosteroids are indicated for the relief of the inflammatory and pruritic manifestations of corticosteroid-responsive dermatoses.

  • CONTRAINDICATIONS

    Topical corticosteroids are contraindicated in those patients with a history of hypersensitivity to any of the components of the preparation

  • PRECAUTION

    General: Systemic absorption of topical corticosteroids has produced reversible hypothalamic-pituitary-adrenal (HPA) axis suppression, manifestations of Cushing's syndrome, hyperglycemia, and glucosuria in some patients. Conditions which augment systemic absorption include the application of the more potent steroids, use over large surface areas, prolonged use, and the addition of occlusive dressings. Therefore, patients receiving a large dose of a potent steroid applied to a large surface area or under occlusive dressing should be evaluated periodically for evidence of HPA axis suppression by using the urinary free cortisol and ACTH stimulation tests. If HPA axis suppression is noted, an attempt should be made to withdraw the drug, to reduce the frequency of application, or to substitute a less potent steroid. Recovery of HPA axis function is generally prompt and complete upon discontinuation of the drug.Infrequently, signs and symptoms of steroid withdrawal may occur, requiring supplemental systemic corticosteroids. Children may absorb proportionally larger amounts of topical corticosteroids and thus be more susceptible to systemic toxicity (See PRECAUTIONS - Pediatric Use ). If irritation develops, topical corticosteroids should be discontinued and appropriate therapy instituted. In the presence of dermatological infections, the use of an appropriate antifungal or antibacterial agent should be instituted. If a favorable response does not occur promptly, the corticosteroid should be discontinued until the infection has been adequately controlled.

    Information for the Patient: Patients using topical corticosteroids should receive the following information and instructions:

    1. This medication is to be used as directed by the physician. It is for external use only. Avoid contact with the eyes.
    2. Patients should be advised not to use this medication for any disorder other than for which it was prescribed.
    3. The treated skin area should not be bandaged or otherwise covered or wrapped as to be occlusive unless directed by the physician.
    4. Patients should report any signs of local adverse reactions especially under occlusive dressings.
    5. Parents of pediatric patients should be advised not to use tight fitting diapers or plastic pants on a child being treated in the diaper area, as these garments may constitute occlusive dressings.

    Laboratory Tests: The following tests may be helpful in evaluating HPA axis suppression: Urinary free cortisol test; ACTH stimulation test.

    Carcinogenesis, Mutagenesis, and Impairment of Fertility: Long-term animal studies have not been performed to evaluate the carcinogenic potential or the effect on fertility of topical corticosteroids. Studies to determine mutagenicity with prednisolone and hydrocortisone have revealed negative results.

    Pregnancy Category C: Corticosteroids are generally teratogenic in laboratory animals when administered systemically at relatively low dosage levels. The more potent corticosteroids have been shown to be teratogenic after dermal application in laboratory animals. There are no adequate and well-controlled studies in pregnant owomen on teratogenic effects from topically applied corticosteroids. Therefore, topical corticosteroids should be used during pregnancy only if the potential benefit justifies the potential risk to the fetus. Drugs of this class should not be used extensively on pregnant patients, in large amounts, or for prolonged periods of time.

    Nursing Mothers: It is not known whether topical administration of corticosteroids could result in sufficient systemic absorption to produce detectable quantities in breast milk. Systemically administered corticosteroids are secreted into breast milk in quantities not likely to have a deleterious effect on the infant. Nevertheless, caution should be exercised when topical corticosteroids are administered to a nursing woman.

    Pediatric Use:Pediatric patients may demonstrate greater susceptibility to topical corticosteroid-induced HPA axis suppression and Cushing's syndrome than mature patients because of a larger skin surface area to body weight ratio. Hypothalamic-pituitary-adrenal (HPA) axis suppression, Cushing's syndrome, and intracranial hypertension have been reported in children receiving topical corticosteroids. Manifestations of adrenal suppression in children include linear growth retardation, delayed weight gain, low plasma cortisol levels, and absence of response to ACTH stimulation. Manifestations of intracranial hypertension include bulging fontanelles, headaches, and bilateral papilledema. Administration of topical corticosteroids to children should be limited to the least amount compatible with an effective therapeutic regimen. Chronic corticosteroid therapy may interfere with the growth and development of children.

  • ADVERSE REACTIONS

    The following local adverse reactions are reported infrequently with topical corticosteroids, but may occur more frequently with the use of occlusive dressings. These reactions are listed in an approximate decreasing order of occurrence: burning, itching, irritation, dryness, folliculitis, hypertrichosis, acneiform eruptions, hypopigmentation, perioral dermatitis, allergic contact dermatitis, maceration of the skin, secondary infection, skin atrophy, striae and miliaria.

  • OVERDOSAGE

    Topically applied corticosteroids can be absorbed in sufficient amounts to produce systemic effects (SeePRECAUTIONS ).

  • DOSAGE AND ADMINISTRATION

    Topical corticosteroids are generally applied to the affected area as a thin film three or four times daily depending on the severity of the condition. Occlusive dressings may be used for the management of psoriasis or recalcitrant conditions. If an infection develops, the use of occlusive dressings should be discontinued and appropriate antimicrobial therapy instituted.

  • HOW SUPPLIED


    Fluocinolone Acetonide Cream USP, 0.01%Fluocinolone Acetonide Cream USP, 0.025%
    15 gram tubeNDC 0168-0058-1515 gram tubeNDC 0168-0060-15
    60 gram tubeNDC 0168-0058-6060 gram tubeNDC 0168-0060-60

    Store at controlled room temperature 15°-30°C (59°-86°F).

    Avoid excessive heat. Protect from freezing.

    E. FOUGERA and CO.
    a division of Nycomed US Inc.
    MELVILLE, NEW YORK 11747

    I25815D

    R12/07
    #43


  • PACKAGE LABEL

    FLUOCINOLONE ACETONIDE CREAM 0.1%, 15GM

    Label Image

  • INGREDIENTS AND APPEARANCE
    FLUOCINOLONE ACETONIDE 
    fluocinolone acetonide cream
    Product Information
    Product TypeHUMAN PRESCRIPTION DRUGItem Code (Source)NDC:16590-097(NDC:0168-0058)
    Route of AdministrationTOPICAL
    Active Ingredient/Active Moiety
    Ingredient NameBasis of StrengthStrength
    fluocinolone acetonide (UNII: 0CD5FD6S2M) (fluocinolone acetonide - UNII:0CD5FD6S2M) fluocinolone acetonide 0.1 mg  in 1 g
    Inactive Ingredients
    Ingredient NameStrength
    stearic acid (UNII: 4ELV7Z65AP)  
    propylene glycol (UNII: 6DC9Q167V3)  
    sorbitan monostearate (UNII: NVZ4I0H58X)  
    sorbitan monooleate (UNII: 06XEA2VD56)  
    polysorbate 60 (UNII: CAL22UVI4M)  
    anhydrous citric acid (UNII: XF417D3PSL)  
    methylparaben (UNII: A2I8C7HI9T)  
    propylparaben (UNII: Z8IX2SC1OH)  
    water (UNII: 059QF0KO0R)  
    Packaging
    #Item CodePackage DescriptionMarketing Start DateMarketing End Date
    1NDC:16590-097-1515 g in 1 TUBE
    Marketing Information
    Marketing CategoryApplication Number or Monograph CitationMarketing Start DateMarketing End Date
    ANDAANDA08817012/16/1982
    Labeler - STAT RX USA LLC (786036330)
    Establishment
    NameAddressID/FEIBusiness Operations
    STAT RX USA LLC786036330relabel, repack