Label: HELIUM OXYGEN NITROGEN MIXTURE gas

  • Category: HUMAN PRESCRIPTION DRUG LABEL
  • DEA Schedule: None
  • Marketing Status: unapproved medical gas

DISCLAIMER: This drug has not been found by FDA to be safe and effective, and this labeling has not been approved by FDA. For further information about unapproved drugs, click here.

Drug Label Information

Updated July 29, 2013

If you are a consumer or patient please visit this version.

  • PRINCIPAL DISPLAY PANEL

    UN1956

    GASES,

    N.O.S.

    (OXYGEN,

    HELIUM, NITROGEN)

    % OXYGEN USP CAS: 7782-44-7

    % HELIUM USP CAS: 7740-59-7

    % NITROGEN NF CAS: 7727-37-9

    NET CONTENTS

    LOT NUMBER

    CAUTION! HIGH-PRESSURE GAS. MAY ACCELERATE COMBUSTION. CONCENTRATIONS BELOW 19.5% OXYGEN CAN CAUSE RAPID ASPHYXIATION MAY CAUSE DIZZINESS AND DROWSINESS.

    Keep oil, grease, and combustibles away. Keep away from heat, sparks, and flame. Store and use with adequate ventilation. Use with equipment rated for cylinder pressure and cleaned for oxygen service. Use a backflow prevention device in any piping. Cylinder temperature should not exceed 125°F (52°C). Open valve slowly. Close valve after each use; keep closed even when empty. Always secure cylinder. Install cap, if provided, when not in use. Use per Praxair MSDS provided and safe practices booklets P-3499 and P-14-153; obtain from your local supplier.

    FIRST AID: IF INHALED, remove to fresh air. If not breathing, give artificial respiration. If breathing is difficult, qualified personnel may give oxygen. Call a physician.

    RX ONLY

    WARNING! Administration of this gas mixture may be hazardous or contraindicated. For use only by or under the supervision of a licensed

    practitioner who is experienced in the use and administration of gas mixtures and is familiar with the indications, effects, dosages, methods and

    frequency and duration of administration, and with the hazards, contraindications, and side effects and the precautions to be taken.

    Rx only IN CASE OF EMERGENCY CALL 1-800-645-4633

    Copyright @ 1997-1998, 2003, 2006, Praxair Technology, Inc.

    DO NOT REMOVE THIS LABEL MMG-7 (07/06)

    Praxair, the flowing airstream design and Medipure are trademarks of Praxair Technology, Inc. DISTRIBUTED BY PRAXAIR, INC, DANBURY, CT 06810-5113label one

  • PRINCIPAL DISPLAY PANEL

    UN3156

    COMPRESSED GAS,

    OXIDIZING N.O.S.

    (OXYGEN, HELIUM, NITROGEN)

    % OXYGEN USP CAS: 7782-44-7

    % HELIUM USP CAS: 7740-59-7

    % NITROGEN NF CAS: 7727-37-9

    NET CONTENTS

    LOT NUMBER

    WARNING! HIGH-PRESSURE OXIDIZING GAS. VIGOROUSLY ACCELERATES COMBUSTION

    Keep oil, grease, and combustibles away. Store and use with adequate ventilation. Use only with equipment rated for cylinder pressure and cleaned for oxygen service. Cylinder temperature should not exceed 125°F (52°C). Open valve slowly. Close valve after each use; keep closed even when empty. Always secure cylinder. Install cap, if provided, when not in use. Use per Praxair MSDS provided and safe practices booklets P-3499 and P-14-153; obtain from your local supplier.

    FIRST AID: IF INHALED, remove to fresh air. If not breathing, give artificial respiration. If breathing is difficult, qualified personnel may give oxygen. Call a physician.

    RX ONLY

    WARNING! Administration of this gas mixture may be hazardous or contraindicated. For use only by or under the supervision of a licensed

    practitioner who is experienced in the use and administration of gas mixtures and is familiar with the indications, effects, dosages, methods and

    frequency and duration of administration, and with the hazards, contraindications, and side effects and the precautions to be taken.

    Rx only IN CASE OF EMERGENCY CALL 1-800-645-4633

    Copyright @ 1997-1998, 2003, 2005, Praxair Technology, Inc.

    DO NOT REMOVE THIS LABEL MMG-7-0 (10/05)

    Praxair, the flowing airstream design and Medipure are trademarks of Praxair Technology, Inc. DISTRIBUTED BY PRAXAIR, INC, DANBURY, CT 06810-5113label two

  • INGREDIENTS AND APPEARANCE
    HELIUM OXYGEN NITROGEN MIXTURE 
    helium oxygen nitrogen mixture gas
    Product Information
    Product TypeHUMAN PRESCRIPTION DRUGItem Code (Source)NDC:49972-010
    Route of AdministrationRESPIRATORY (INHALATION)
    Active Ingredient/Active Moiety
    Ingredient NameBasis of StrengthStrength
    HELIUM (UNII: 206GF3GB41) (HELIUM - UNII:206GF3GB41) HELIUM200 mL  in 1 L
    OXYGEN (UNII: S88TT14065) (OXYGEN - UNII:S88TT14065) OXYGEN500 mL  in 1 L
    NITROGEN (UNII: N762921K75) (NITROGEN - UNII:N762921K75) NITROGEN300 mL  in 1 L
    Packaging
    #Item CodePackage DescriptionMarketing Start DateMarketing End Date
    1NDC:49972-010-017900 L in 1 CYLINDER
    2NDC:49972-010-025975 L in 1 CYLINDER
    3NDC:49972-010-032010 L in 1 CYLINDER
    4NDC:49972-010-04963 L in 1 CYLINDER
    5NDC:49972-010-05595 L in 1 CYLINDER
    6NDC:49972-010-06368 L in 1 CYLINDER
    Marketing Information
    Marketing CategoryApplication Number or Monograph CitationMarketing Start DateMarketing End Date
    unapproved medical gas10/01/2005
    Labeler - Praxair Distribution Southeast LLC (008455552)
    Establishment
    NameAddressID/FEIBusiness Operations
    Praxair Distribution Southeast LLC006734263manufacture(49972-010)