Label: TECHNESCAN PYP- technetium tc 99m pyrophosphate injection, powder, lyophilized, for solution

  • Category: HUMAN PRESCRIPTION DRUG LABEL
  • DEA Schedule: None
  • Marketing Status: New Drug Application

Drug Label Information

Updated June 7, 2024

If you are a consumer or patient please visit this version.

  • DESCRIPTION
    Technescan™ PYP™ (Kit for the Preparation of Technetium Tc 99m Pyrophosphate Injection) is a sterile, non-pyrogenic, diagnostic radiopharmaceutical suitable for intravenous administration after ...
  • PHYSICAL CHARACTERISTICS
    Technetium Tc 99m decays by isomeric transition with a physical half-life of 6.02 hours. 1The principal photon that is useful for detection and imaging is listed in Table 1. Table 1 ...
  • CLINICAL PHARMACOLOGY
    When injected intravenously, Technetium Tc 99m Pyrophosphate has a specific affinity for areas of altered osteogenesis. It is also concentrated in the injured myocardium, primarily in areas of ...
  • INDICATIONS AND USAGE
    Technetium Tc 99m Pyrophosphate Injection is a skeletal imaging agent used to demonstrate areas of altered osteogenesis, and a cardiac imaging agent used as an adjunct in the diagnosis of acute ...
  • CONTRAINDICATIONS
    None known.
  • WARNINGS
    Reports indicate impairment of brain images using sodium pertechnetate Tc 99m, which have been preceded by a bone image. The impairment may result in false positives or false negatives. It is ...
  • PRECAUTIONS
    General - Technescan PYP should not be used more than six hours after preparation. The components of the kit are sterile and non-pyrogenic. It is essential that the user follow the directions ...
  • ADVERSE REACTIONS
    Several adverse reactions due to the use of Technetium Tc 99m Pyrophosphate Injection have been reported. These were usually flushing, hypotension, fever, chills, nausea, vomiting and dizziness ...
  • DOSAGE AND ADMINISTRATION
    Bone and Cardiac Imaging - The recommended adult doses of Technetium Tc 99m Pyrophosphate Injection are:  Indication Doses as - Technetium Tc 99 -  Fraction of - Vial ...
  • RADIATION DOSIMETRY
    Method of Calculation: The following radiation absorbed dose values were obtained using the Medical Internal Radiation Dose Committee (MIRD) Schema. Bone and Cardiac Imaging - Maximum Dose: 555 ...
  • HOW SUPPLIED
    Catalog Number 094. Technescan PYP is supplied as a lyophilized powder packaged in vials. Each vial contains 11.9 mg sodium pyrophosphate, 3.2 mg (minimum) stannous chloride (SnCl - 2•2H - 2O ...
  • INSTRUCTIONS FOR PREPARING THE DRUG
    Procedural Precautions - All transfer and vial stopper entries must be done using aseptic techniques. Procedure - Bone and Cardiac Imaging - Note 1:Wear waterproof gloves during the ...
  • SPL UNCLASSIFIED SECTION
    This reagent kit is approved for distribution to persons licensed by the U.S. Nuclear Regulatory Commission to use byproduct material identified in Section 35.200 or under an equivalent license of ...
  • PRINCIPAL DISPLAY PANEL - A094V0
    Technescan™ PYP™ (Stannous Pyrophosphate) Vial contains 11.9 mg Sodium Pyrophosphate, 3.2 mg (minimum) stannous chloride (SnCl - 2•2H - 2O) and 4.4 mg (maximum) total tin as stannous ...
  • INGREDIENTS AND APPEARANCE
    Product Information