DEXAMETHASONE SODIUM PHOSPHATE- dexamethasone sodium phosphate injection, solution
Fresenius Kabi USA, LLC
----------
INSTRUCTIONS FOR USE
Figure 1: Outer Packaging and Prefilled Syringe
NOTES:
-
- - Do not introduce any other fluid into the syringe at any time.
-
- - Do not dilute for IV push.
-
- - Do not re-sterilize the syringe.
-
- - Do not use this product on a sterile field.
-
- - This product is for single dose only.
- 1.
- Inspect the outer packaging (blister pack) to confirm the integrity of the packaging. Do not use if the blister pack or the prefilled syringe has been damaged.
- 2.
- Remove the syringe from the outer packaging. (See Figure 2)
-
-
Figure 2
-
-
- 3.
- Visually inspect the syringe. Parenteral drug products should be inspected visually for particulate matter and discoloration prior to administration, whenever solution and container permit.
- 4.
- Twist off the syringe tip cap. Do not remove the label around the luer lock collar. (See Figure 3)
-
-
Figure 3
-
-
- 5.
- Expel air bubble(s). Adjust the dose (if applicable).
- 6.
- Administer the dose ensuring that pressure is maintained on the plunger rod during the entire administration.
- 7.
- Discard the used syringe into an appropriate receptacle.
For more information concerning this drug, please call Fresenius Kabi USA, LLC at 1-800-551-7176.
To report SUSPECTED ADVERSE REACTIONS, contact Fresenius Kabi USA, LLC at 1-800-551-7176 or FDA at 1-800-FDA-1088 or www.fda.gov/medwatch.