ENCORE- estradiol, oxytetracycline implant
Elanco US Inc.
----------
Elanco™
AH0347
Encore™
(estradiol implant)
Each implant consists of 43.9 mg estradiol
400 Day Controlled Release Implants
Each Encore (estradiol implant) silicone rubber implant contains 43.9 mg estradiol and is coated with not less than 0.5 mg of oxytetracycline powder as a local antibacterial.
For subcutaneous ear implantation in steers and heifers only.
For increased rate of weight gain in suckling and pastured growing steers; for improved feed efficiency and increased rate of weight gain in confined steers and heifers. Do not use in veal calves. Effectiveness and animal safety in veal calves have not been established.
An Encore Controlled Release Implant will provide an effective daily dose of estradiol for at least 400 days. No additional effectiveness may be expected from reimplanting in less than 400 days.
Suckling steers
At castration or later
Pastured growing steers
At weaning or later
Finishing steers and heifers
At arrival in feedlot
Keep out of reach of children.
A withdrawal period has not been established for this product in pre-ruminating calves. Do not use in calves to be processed for veal.
A Compudose™ (estradiol implant) or Encore (estradiol implant) Implanter must be used to implant cattle.
Insert one implant under the skin of the ear.
Use a sharp needle. The needle should be cleaned and sterilized between each injection by wiping the exterior with a sponge, cloth, or gauze saturated with an appropriate disinfectant. The presence of excessive moisture inside the needle may result in dissolving the oxytetracycline (OTC) from the implant surface and contribute to accumulation of OTC inside the needle.
Grasping the tip of the ear with one hand and the implanter in the other, penetrate the skin in the outer third of the ear.
(see Figure 2)
IMPORTANT: Do not penetrate cartilage.
Upon penetration, the needle should be fully inserted (Figure 3) between the skin and cartilage, avoiding major blood vessels. Full insertion of the needle is important to maximize implant retention.
Proper Position
CAUTION: To maximize implant retention:
The needle has been scientifically designed to maximize retention. When it becomes dull, use a new needle. If the needle is resharpened, sharpen only the point.
Failure to follow antiseptic implanting procedures, particularly when the ears are contaminated with fecal material, may result in infection and excessive implant loss. Implanting cattle during wet weather may increase infection and implant loss.
Carefully check the ears for implant loss approximately 4 weeks after implantation. If loss occurs, reimplant using recommended procedures.
CAUTION: Increased sexual activity (bulling, riding and excitability) has been reported in animals implanted with Encore. Implanted animals should be observed for such signs particularly during the first few days after implanting and animals being excessively ridden (bullers) should be removed to prevent physical injury. Vaginal and rectal prolapse have been reported in heifers implanted with Encore.
CAUTION: Do not use in animals intended for breeding purposes.
Udder development, swollen or enlarged vulva and high tailheads may be observed in implanted heifers.
Encore Implants are supplied in cartridges of 20 implants each.
NADA 118-123, Approved by FDA
Manufactured by a non-sterilizing process.
Encore, Compudose, Elanco and the diagonal bar logo are trademarks of Elanco or its affiliates.
Distributed by Elanco US, Inc.
Greenfield, IN 46140, USA
Product of Germany
To report adverse events, access medical information, or to obtain additional product information, call 1-800-428-4441
ENCORE
estradiol, oxytetracycline implant |
||||||||||||||||||||
|
||||||||||||||||||||
|
||||||||||||||||||||
|
||||||||||||||||||||
|
Labeler - Elanco US Inc. (966985624) |
Establishment | |||
Name | Address | ID/FEI | Business Operations |
---|---|---|---|
Ivy Animal Health, Inc. | 088106096 | MANUFACTURE, PACK, LABEL |
Establishment | |||
Name | Address | ID/FEI | Business Operations |
---|---|---|---|
Bayer AG | 314398484 | API MANUFACTURE |
Establishment | |||
Name | Address | ID/FEI | Business Operations |
---|---|---|---|
Hebei Jianmin Starch Glucose Co., Ltd. | 529723751 | API MANUFACTURE |