CPDA-1 - anticoagulant citrate phosphate dextrose adenine solution 
Fenwal, Inc.

----------

Double Blood-Pack™ Unit Anticoagulant Citrate Phosphate Dextrose Adenine Solution (CPDA-1)

Instructions for Blood Collection Using (CPDA-1) BLOOD-PACK™ Unit

Rx Only

Integral Donor Tube (IDT)

Use aseptic technique.

Caution: Do not use unless the solutions are clear.

1.
Identify BLOOD-PACK™ unit using appropriate donor identification system.
2.
Adjust donor scale to desired collection weight/volume.
3.
Suspend primary container from donor scale as far as possible below donor arm and clamp donor tubing at Position 1 (see Figure 1). Use one of the clamps that come inside the aluminum pouch.
4.
Apply pressure to donor’s arm and disinfect site of venipuncture.
5.
If blood pressure cuff is used, inflate to approximately 60 mm Hg.
6.
Remove needle cover per instructions below:
a)
Hold the needle hub upwards. With the other hand, grasp the base of the needle cover (Figure 2), twist approximately 1/4 turn to break tamper evident seal (Figure 3).
b)
Remove needle cover (Figure 4), be careful not to drag cover across the needle point (Figure 5).
7.
Perform venipuncture, appropriately secure donor needle and/or tubing and move clamp to Position 2 (Figure 1).
8.
Mix blood and anticoagulant at several intervals during collection and immediately after collection.
9.
Collect labeled volume of blood. Anticoagulant volume is sufficient for labeled volume ± 10%.
10.
Place clamp back to Position 1 (Figure 1).
11.
Seal donor tubing between clamp and primary container (a hand sealer clamp may be used). Dispose of needle and tubing appropriately. Cut between clamp and clip/seal; collect any needed samples using standard techniques.
12.
Release pressure on donor’s arm and withdraw needle.
13.
Strip blood from donor tubing into container, mix and allow the tubing to refill; repeat once. Seal at X marks on donor tubing to provide numbered aliquots of anticoagulated blood for typing or crossmatching.
14.
Store suspended Red Blood Cells between 1 and 6°C.
15.
Infuse suspended Red Blood Cells within 35 days of collection.

NOTE:

In order to establish fluid transfer from primary container to secondary system, hold the cannula by its base with one hand, and with the other hand break the cannula by bending it 90º in one direction, then 180º in the opposite direction (Figure 6).

For further processing, use standard component processing and storage techniques.

Instructions of use illustrations

Dispose of containers and materials into appropriate biohazardous waste containers following established procedures.

Sterile, non-pyrogenic fluid path. Steam sterilized. Single use only.

Store at Controlled Room Temperature.

USP Definition of “Controlled Room Temperature”
United States Pharmacopeia, General Notices.
United States Pharmacopeial Convention, Inc.
12601 Twinbrook Parkway, Rockville, MD

logoManufacturer

logoManufactured by:
Fenwal International, Inc.
Road 357, Km. 0.8
Maricao, PR 00606

Made in USA

Imported and distributed in India by:
Fenwal India Pvt Ltd
Upper Ground Floor, Tower B
DLF Building No. 10, DLF Cyber City
DLF Phase-II, Gurgaon 122 002,
Haryana, India
Import License No.: FF-504-14890

Imported and distributed in Indonesia by:
PT.Medquest Jaya Global
Menara Salemba 6th Floor
Jl.Salemba Raya Kav 5-5A
Jakarta-Indonesia 10440
Reg. No.: DEPKES RI AKL 20209902358

Imported and distributed in Thailand by:
Fenwal (Thailand) Ltd.
17th Fl. Thanapoom Tower,
1550 New Petchburi Rd., Makasan
Rajthevi, Bangkok 10400
Thailand

Imported and distributed in Venezuela by:
SOLUCARE GT, C.A. RIF J-30512494-9
en La Urbina, Caracas,
Republica Bolivariana de Venezuela
TELF (0212) 2436663
Registrado en el MPPS bajo el No:

07-19-07-227 REV: A 05/2012

FENWAL and BLOOD-PACK are trademarks of Fenwal, Inc.

© 2012 Fenwal, Inc. All rights reserved.

PACKAGE/LABEL PRINCIPAL DISPLAY PANEL

Code T4R6202UT

6 Units

Fenwal™

Double Blood-Pack™ Unit Anticoagulant Citrate Phosphate Dextrose Adenine Solution (CPDA-1)

Rx Only

Double Blood-Pack unit for collection of 450 mL of blood, 16 gauge needle.

Each unit consists of a primary container with 63 mL of CPDA-1 USP Solution containing 2.01 g Dextrose (monohydrate), USP, 1.66 g Sodium Citrate (dihydrate), USP, 206 mg Citric Acid (monohydrate), USP, 140 mg Monobasic Sodium Phosphate (monohydrate), USP, 17.3 mg Adenine, USP, Water for Injection USP to 63 mL, and one empty 400 mL transfer pack container.

See instructions for use. Sterile, non-pyrogenic fluid path. Steam sterilized. Single use only. Do not vent. Do not use if there is any visible sign of deterioration. Dispose of container appropriately.

Store at Controlled Room Temperature (refer to direction insert).

Unused units in open foil pouch may be kept to 60 days by folding and securing open end of foil pouch to prevent possible loss of moisture.
Direct handling of product surfaces prior to extended storage in the foil pouch, may result in mold growth.
Units removed from the foil pouch must be used within 4 days (96 hours). Units out of foil pouch for longer than 4 days must be discarded.

logoManufactured by:
Fenwal International, Inc.
Road 357, Km. 0.8
Maricao, PR 00606

Made In USA

07-28-02-070 Rev: A

Imported and distributed in
Thailand by:
Fenwal (Thailand) Ltd.
17th Fl. Thanapoom Tower
1550 New Petchburi Rd.,
Makasan Rajthevi, Bangkok
10400
Thailand
Reg. No.: See Instructions for use

FENWAL and BLOOD-PACK are trademarks of Fenwal, Inc.

Double Blood-Pack Unit Anticoagulant Citrate Phosphate Dextrose Adenine Solution (CPDA-1) label
CPDA-1 
anticoagulant citrate phosphate dextrose adenine solution
Product Information
Product TypeHUMAN PRESCRIPTION DRUGItem Code (Source)NDC:0942-6344
Route of AdministrationINTRAVENOUS
Active Ingredient/Active Moiety
Ingredient NameBasis of StrengthStrength
DEXTROSE MONOHYDRATE (UNII: LX22YL083G) (ANHYDROUS DEXTROSE - UNII:5SL0G7R0OK) DEXTROSE MONOHYDRATE2.01 g  in 63 mL
TRISODIUM CITRATE DIHYDRATE (UNII: B22547B95K) (ANHYDROUS CITRIC ACID - UNII:XF417D3PSL) ANHYDROUS CITRIC ACID1.66 g  in 63 mL
CITRIC ACID MONOHYDRATE (UNII: 2968PHW8QP) (ANHYDROUS CITRIC ACID - UNII:XF417D3PSL) ANHYDROUS CITRIC ACID206 mg  in 63 mL
SODIUM PHOSPHATE, MONOBASIC, MONOHYDRATE (UNII: 593YOG76RN) (PHOSPHATE ION - UNII:NK08V8K8HR) SODIUM PHOSPHATE, MONOBASIC, MONOHYDRATE140 mg  in 63 mL
ADENINE (UNII: JAC85A2161) (ADENINE - UNII:JAC85A2161) ADENINE17.3 mg  in 63 mL
Inactive Ingredients
Ingredient NameStrength
WATER (UNII: 059QF0KO0R)  
Packaging
#Item CodePackage DescriptionMarketing Start DateMarketing End Date
1NDC:0942-6344-0263 mL in 1 BAG; Type 0: Not a Combination Product
Marketing Information
Marketing CategoryApplication Number or Monograph CitationMarketing Start DateMarketing End Date
NDABN77042012/04/201209/30/2014
Labeler - Fenwal, Inc. (794519020)
Establishment
NameAddressID/FEIBusiness Operations
Fenwal International, Inc.091164590MANUFACTURE(0942-6344)

Revised: 12/2018
 
Fenwal, Inc.