OXYGEN- oxygen gas 
Ohio Valley Acquisition Corp dba Ohio Valley Medical Gas & Supply, Inc.

----------

OXYGEN REFRIGERATED LIQUID USP LABEL

REFRIGERATED LIQUID

OXYGEN, REFRIGERATED LIQUID USP UN1073

OXYGEN 2

WARNING: For emergency use only when administered by properly trained personnel for oxygen deficiency and resuscitation. For all other medical applications, Rx only.

Uninterrupted use of high concentrations of oxygen over a long duration, without monitoring its effect on oxygen content of arterial blood, may be harmful. Do not attempt to use on patients who have stopped breathing unless used in conjunction of resuscitative equipment. Keep out of reach of children.

Federal law requires that this container be refilled with oxygen USP only by establishments registered as a drug manufacturer in accordance with the Federal Food, Drug, and Cosmetic Act.

Produced by Air Liquefaction.

DANGER: MAY CAUSE OR INTENSIFY FIRE; OXIDER, CONTAINS REFRIGERATED GAS; MAY CAUSE CRYOGENIC BURNS OR INJURY. COMBUSTIBELS IN CONTACT WITH LIQUID OXYGEN MAY EXPLODE ON IGNITION OR IMPACT.

Do not handle until all safety precautions have been read and understood. Keep and store away from clothing and other combustible materials. Keep valves and fittings free from grease and oil.  Use and store only outdoors or in a well-ventilated place. Wear cold insulating gloves, face shield, and eye protection. In case of fire: Stop leak if safe to do so. Use a back flow preventive device in the piping. Use only the equipment of compatible materials equipment cleaned for oxygen service. DO NOT change or force fit connections. Avoid spills. Do not walk on or roll equipment over spills. Close valve after each use and when empty. Always keep container in upright position. Read and follow the Safety Data Sheet (SDS) before use.

FIRST AID FIRST AID: IF ON SKIN: Thaw affected parts with lukewarm water. Do not rub affected area. Get immediate medical advice/attention.

CAS: 7782-44-7 

DO NOT REMOVE THIS PRODUCT LABEL

OHIO VALLEY MEDICAL GAS & SUPPLY

1415 NORTH ROYAL AVE.

EVANSVILLE, IN 47715 • 812-423-3617

LIQUID LABEL

OXYGEN 
oxygen gas
Product Information
Product TypeHUMAN PRESCRIPTION DRUGItem Code (Source)NDC:75892-001
Route of AdministrationRESPIRATORY (INHALATION)
Active Ingredient/Active Moiety
Ingredient NameBasis of StrengthStrength
OXYGEN (UNII: S88TT14065) (OXYGEN - UNII:S88TT14065) OXYGEN99 L  in 100 L
Packaging
#Item CodePackage DescriptionMarketing Start DateMarketing End Date
1NDC:75892-001-0121 L in 1 DEWAR; Type 0: Not a Combination Product12/22/2010
2NDC:75892-001-0231 L in 1 DEWAR; Type 0: Not a Combination Product12/22/2010
3NDC:75892-001-0335 L in 1 DEWAR; Type 0: Not a Combination Product12/22/2010
4NDC:75892-001-0440 L in 1 DEWAR; Type 0: Not a Combination Product12/22/2010
5NDC:75892-001-0545 L in 1 DEWAR; Type 0: Not a Combination Product12/22/2010
Marketing Information
Marketing CategoryApplication Number or Monograph CitationMarketing Start DateMarketing End Date
NDANDA20602312/22/2010
Labeler - Ohio Valley Acquisition Corp dba Ohio Valley Medical Gas & Supply, Inc. (626351451)
Registrant - Ohio Valley Acquisition Corp dba Ohio Valley Medical Gas & Supply, Inc. (626351451)
Establishment
NameAddressID/FEIBusiness Operations
Ohio Valley Medical Gas & Supply, Inc.626351451manufacture(75892-001)

Revised: 11/2022
Document Id: 6abddf99-ab1d-4287-bd30-6dacb318581d
Set id: b7f09350-2b95-4cab-8ac1-effbf4339c45
Version: 7
Effective Time: 20221104
 
Ohio Valley Acquisition Corp dba Ohio Valley Medical Gas & Supply, Inc.