OXYGEN- oxygen gas 
Badger Welding Supplies, Inc.

----------

OXYGEN - 001

OXYGEN COMPRESSED USP LABEL

OXYGEN COMPRESSED USP

UN 1072

PRODUCED BY AIR LIQUEFACTION

OXYGEN 2

17033 (12/14)

WARNING: For emergency use only when administered by properly trained personnel for oxygen deficiency and resuscitation. For all other medical applications, Rx Only. Uninterrupted use of high concentrations of oxgen over a long duration, without monitoring its effect on oxygen content of arterial blood, may be harmful. Do not attempt to use on patients who have stopped breathing unless it is in conjunction with resuscitative equipment. Keep out of reach of children. Federal law requires that this container be refilled with oxygen USP only by establishments registered as a drug manufacture in accordance with the Federal Food, Drug and Cosmetic Act. DANGER: MAY CAUSE OR INTENSIFY FIRE; OXIDIZER. CONTAINS GAS UNDER PRESSURE. MAY EXPLODE IF HEATED. Do not handle until all safety precautions have been read and understood. Keep and store away from clothing and other combustible materials. Keep valves and fittings free from grease and oil. Use and store only outdoors or in a well-ventilated place. In case of fire:Stop leak if safe to do so. Use a back flow preventive device in the piping. Use only with equipment of compatible materials of construction and rated for cylinder pressure. Use only with equipment cleaned for oxygen service. Open valve slowly. Close valve after each use and when empty. Protect from sunlight when ambient temperature exceeds 52°C (125°F). Read and follow the Safety Data Sheet (SDS) before use.     CAS: 7782-44-7      DO NOT REMOVE THIS PRODUCT LABEL

BADGER WELDING SUPPLIES, INC.
101 SOUTH DICKSON STREET  MADISON WI 53703

608-257-5606

CONTENTS:     CU. FT. _______________  LTRS. __________

Badger HP SL O2

Badger HP SL O2

OXYGEN REFRIGERATED LIQUID USP LABEL

REFIGERATED LIQUID

OXYGEN REFRIGERATED LIQUID USP

 UN 1073

OXYGEN 2

CONTENTS: _____________________________________LTRS: ______________ CU. FT: _______________________

WARNING: For emergency use only when administered by properly trained personnel for oxygen deficiency and resuscitation. For all other medical applications, Rx Only. Uninterrupted use of high concentrations of oxgen over a long duration, without monitoring its effect on oxygen content of arterial blood, may be harmful. Do not attempt to use on patients who have stopped breathing unless it is in conjunction with resuscitative equipment. Keep out of reach of children. Federal law requires that this container be refilled with oxygen USP only by establishments registered as a drug manufacture in accordance with the Federal Food, Drug and Cosmetic Act.

Produced by Air Liquefaction.

DANGER: MAY CAUSE OR INTENSIFY FIRE; OXIDIZER. CONTAINS REFIGERATED GAS: MAY CAUSE CRYOGENIC BURNS OR INJURY. COMBUSTIBLES IN CONTACT WITH LIQUID OXYGEN MAY EXPLODE ON IGNITION OR IMPACT. Do not handle until all safety precautions have been read and understood. Keep and store away from clothing and other combustible materials. Keep valves and fittings free from grease and oil. Use and store only outdoors or in a well-ventilated place. Wear cold insulating gloves, face shield, and eye protection. In case of fire:Stop leak if safe to do so. Use a back flow preventive device in the piping. Use only with equipment of compatible materials of construction and rated for cylinder pressure. Use only with equipment cleaned for oxygen service. DO NOT change or force fit connections. Avoid spills. Do not walk or roll equipment over spills. Close valve after each use and when empty. Always keep container in upright position. Read and follow the Safety Data Sheet (SDS) before use.

FIRST AID: IF ON SKIN: Thaw frosted parts with lukewarm water. Do not rub affected area. Get immediate medical advise/attention. 

CAS: 7782-44-7

DO NOT REMOVE THIS PRODUCT LABEL

BADGER WELDING SUPPLIES, INC.
101 SOUTH DICKSON STREET • MADISON, WI 53703

608-257-5606

47136 (03/17)

Badger Liq O2

OXYGEN 
oxygen gas
Product Information
Product TypeHUMAN PRESCRIPTION DRUGItem Code (Source)NDC:12121-001
Route of AdministrationRESPIRATORY (INHALATION)
Active Ingredient/Active Moiety
Ingredient NameBasis of StrengthStrength
OXYGEN (UNII: S88TT14065) (OXYGEN - UNII:S88TT14065) OXYGEN99 L  in 100 L
Packaging
#Item CodePackage DescriptionMarketing Start DateMarketing End Date
1NDC:12121-001-01141 L in 1 CYLINDER; Type 0: Not a Combination Product01/01/1955
2NDC:12121-001-02234 L in 1 CYLINDER; Type 0: Not a Combination Product01/01/1955
3NDC:12121-001-03387 L in 1 CYLINDER; Type 0: Not a Combination Product01/01/1955
4NDC:12121-001-04643 L in 1 CYLINDER; Type 0: Not a Combination Product01/01/1955
5NDC:12121-001-051738 L in 1 CYLINDER; Type 0: Not a Combination Product01/01/1955
6NDC:12121-001-063511 L in 1 CYLINDER; Type 0: Not a Combination Product01/01/1955
7NDC:12121-001-077051 L in 1 CYLINDER; Type 0: Not a Combination Product01/01/1955
8NDC:12121-001-09127400 L in 1 DEWAR; Type 0: Not a Combination Product01/01/1955
Marketing Information
Marketing CategoryApplication Number or Monograph CitationMarketing Start DateMarketing End Date
NDANDA20576701/01/1955
Labeler - Badger Welding Supplies, Inc. (023314099)
Registrant - Badger Welding Supplies, Inc. (023314099)
Establishment
NameAddressID/FEIBusiness Operations
Badger Welding Supplies, Inc.023314099manufacture(12121-001)

Revised: 10/2023
Document Id: b4570888-dfc3-441b-a8dd-fa059862aa45
Set id: 865454e8-ea25-4b6d-85c6-9db055eb3116
Version: 14
Effective Time: 20231016
 
Badger Welding Supplies, Inc.