Oxygen, Compressed USP UN1072

WARNING:  For emergency use only when administered by properly trained personnel for Oxygen deficiency and resuscitation.  For all other medical applications, Rx only.  Uninterrupted use of high-concentrations of Oxygen over a long duration, without monitoring its effect on oxygen content of arterial blood, may be harmful.  Use only with pressure reducing equipment and apparatus designed for Oxygen.  Do not attempt to use on patients who have stopped breathing, unless used in conjunction with resuscitative equipment.  Produced by Air Liquefaction.

WARNING:  HIGH PRESSURE OXIDIZING GAS.  VIGOROUSLY ACCELERATES COMBUSTION.  Keep oil and grease away.  Open valve slowly.  Store and use with adequate ventilation.  Use only with equipment cleaned for Oxygen service and rated for cylinder pressure.  Use a back flow preventive device in piping.  Close valve after each use and when empty.  Cylinder temperature should not exceed 52*C (125*F).  Use in accordance with the Material Safety Data Sheet (MSDS).
CAS:  7782-44-7
                                                                            DO NOT REMOVE THIS PRODUCT LABEL

Manufactured By:
Allens CTI
5206 Industrial Way Suite B, Anderson, CA  96007
(530) 378-5196
OXYGEN 
oxygen gas
Product Information
Product TypeHUMAN PRESCRIPTION DRUGItem Code (Source)NDC:49790-001
Route of AdministrationRESPIRATORY (INHALATION)
Active Ingredient/Active Moiety
Ingredient NameBasis of StrengthStrength
Oxygen (UNII: S88TT14065) (Oxygen - UNII:S88TT14065) Oxygen992 mL  in 1 L
Packaging
#Item CodePackage DescriptionMarketing Start DateMarketing End Date
1NDC:49790-001-0142 L in 1 CYLINDER
2NDC:49790-001-02113 L in 1 CYLINDER
3NDC:49790-001-03170 L in 1 CYLINDER
4NDC:49790-001-04198 L in 1 CYLINDER
5NDC:49790-001-05255 L in 1 CYLINDER
6NDC:49790-001-06425 L in 1 CYLINDER
7NDC:49790-001-07623 L in 1 CYLINDER
8NDC:49790-001-08680 L in 1 CYLINDER
9NDC:49790-001-091699 L in 1 CYLINDER
10NDC:49790-001-102549 L in 1 CYLINDER
11NDC:49790-001-113455 L in 1 CYLINDER
12NDC:49790-001-124248 L in 1 CYLINDER
Marketing Information
Marketing CategoryApplication Number or Monograph CitationMarketing Start DateMarketing End Date
unapproved medical gas11/04/2009
Labeler - Allen's Cylinder Testing & Inspection Company (005292460)
Establishment
NameAddressID/FEIBusiness Operations
Allen's Cylinder Testing & Inspection Company005292460manufacture

Revised: 11/2009
Document Id: 74d8d839-3cf1-4fbf-bc2b-4999f577c7f4
Set id: 6522d8a4-2658-444d-8412-d2a2fe0532b3
Version: 1
Effective Time: 20091104
 
Allen's Cylinder Testing & Inspection Company